44 Release and Migration Notes - Bugfixes Included with Barracuda NG Firewall 5.2.3
Bugfixes Included with Barracuda NG Firewall 5.2.3
Barracuda NG Admin
Barracuda NG Installer
Table 1–4 Barracuda NG Admin
Description
In rare cases, the Connection Object editor erroneously requested the user to select an object although this was actually not
needed. This issue was fixed.
In rare cases, Barracuda NG Admin 5.2.2 was crashing in case loading config from the NG Control Center failed. This issue was
fixed.
The Group VPN Settings > LDAP Attributes > IP Attribute Name length was erroneously limited to a length of 21 characters.
This issue was fixed.
Certain issues regarding the conversion of netmask notation types in Barracuda NG Admin were fixed.
Authentication options TACACS+ and NGF Local were erroneously not available for NG Control Center Admins. This issue was
fixed.
The Open Configuration for... dialog in the Control Center Status map did not work as intended if logging in was carried out using
a DNS name instead of an IP address. This issue was fixed.
It was erroneously possible to add duplicate entries to configuration lists. This issue was fixed.
Attempts to log in using an unresolvable hostname were generating a meaningless error message instead of pointing the user to the
actual problem. This issue was fixed.
In firmware release versions 5.2.x, it was erroneously not possible to export a whole set of licenses to the clipboard or to use the
Copy, Merge and Replace buttons for more than one license concurrently. This issue was fixed.
On a Barracuda NG Control Center, it was erroneously not possible to check the checkboxes in the Name column within Control >
Firmware Update if the dialog was displayed on the secondary monitor of the workstation. This issue was fixed.
Barracuda NG Admin 5.2.x crashed on Barracuda NG Control Center units if a file was dragged from the Files section within
Control > Firmware Update to the main section above. This issue was fixed.
It was erroneously not possible to remove multiple connection objects or interface groups from a forwarding rule at once. As soon as
more than one item was selected, the Delete button didn’t have any effect anymore. This issue was fixed.
Copying and pasting access groups within Infrastructure Service > SNMP Service Settings caused the loss of View settings in
the target node. This issue was fixed.
Table 1–5 Barracuda NG Admin
Description
In rare cases, certain units were erroneously detected as XEN units. This issue was fixed.